Use this guide to find out whether your UPVC door lock needs adjustment, repair or replacement before you buy parts.
If a UPVC door won't lock, usual causes are door misalignment, a failed multipoint gearbox, worn keeps or a faulty cylinder. Identify the fault before buying anything: test the lock with the door open, then inspect alignment and locking points carefully.
Don't force a stiff handle or key. A small alignment problem can put strain on the gearbox and turn a simple adjustment into a more involved repair.
A multipoint lock secures the door at several points along its edge. When you lift the handle, the spindle turns inside the centre case, also called the gearbox. The gearbox drives the locking strip, moving hooks, rollers or a deadbolt into metal keeps fitted to the frame. The cylinder operates the lock, usually by turning the key to secure or release the centre case.
If the door is out of alignment, those locking points can hit the edges of the keeps rather than entering smoothly. That resistance can feel like a broken lock, even when the gearbox is still working.
With the door open, gently operate the handle and key. Keep your fingers clear of moving hooks and bolts. If the lock works smoothly when open but becomes difficult when closed, check the door's alignment and the keeps first.
First look at the closed door. The gap between the door and frame should appear reasonably even around the top, sides and bottom. A noticeably tighter gap at one corner, rubbing marks, or a door that needs lifting to latch can point to dropped hinges or a shifted door.
Next, open the door and lift the handle slowly. Watch each hook, roller or bolt as it moves, and note which ones line up poorly with their keeps. This open-door check helps separate a lock mechanism fault from resistance caused by the frame.
If a keep is only slightly out of position, it may be possible to adjust it. Loosen its fixing screws without removing them, move it a small amount, around 1–2 mm to start, then retighten and test. Make only one small change at a time. The aim is for the locking point to enter smoothly while the door sits properly against the seal, not to force the door tightly into the frame.
If the whole strip sits too high or low, the hinges may need adjustment instead. Many UPVC hinges have hex or Allen-key adjusters for height or lateral movement, but designs vary: some use cam-release or other adjustment methods. Follow the hinge manufacturer's instructions and make small changes. If you cannot identify the adjuster or the door is substantially dropped, get a competent person to assess it rather than forcing the hardware.
A gearbox may be at fault if the handle spins without moving the locking strip, you hear grinding, or the locking points move part-way and then stop, even with the door open. A broken internal spring, cam or spindle follower can prevent the handle or key from driving the mechanism properly.
Before ordering a replacement, record:
Measurements and conventions can vary, so don't choose by brand or one measurement alone. Use our multipoint lock measurement guide and compare the complete mechanism with the options in multipoint locks.
Some gearboxes are discontinued or cannot be replaced as a separate case. A compatible multipoint repair lock or full strip replacement may be the practical answer. Photograph the whole faceplate, the gearbox markings and the keeps before ordering. Our Find a Part tool on the website may also help you identify the mechanism.
If only one keep or accessory is worn, replacing that part may be enough. Check the available multipoint accessories and keeps, but match the profile and locking-point type to your existing hardware.
A stiff key, a cylinder that moves in the door, or a key that turns without engaging may point to the cylinder, its fixing screw or its cam. But if the gearbox is under pressure because the door is misaligned, the key can also resist turning. Test the mechanism with the door open before assuming the cylinder has failed.
If you need to replace it, measure both sides from the centre of the fixing screw and label them internal and external. Our guide explains how to measure a euro cylinder. If you're upgrading security, browse anti-snap cylinders. Their design helps resist snapping attacks, but the right size and correct fit still matter.
Call a locksmith if the door is jammed shut, the gearbox needs removing and you are not confident doing the work, or the mechanism on a composite door is unfamiliar. A competent person can identify the cause without damaging the door or leaving it insecure.
For communal doors, fire doors and escape routes, do not adjust or replace hardware by guesswork. Use a competent person and ensure any replacement matches the door's certification and required escape function.
Call 0330 174 0851, Monday to Friday, 9:30am–4:30pm, or email info@lockshopdirect.co.uk. Our certified security experts can talk you through the checks and help you match a mechanism using the measurements from our multipoint lock measurement guide.
Same-day dispatch is available on qualifying orders placed before 5pm, with next-day delivery on selected products. Delivery is free on orders over £60.
Before ordering, work through the multipoint lock measurement guide and have your measurements to hand — that's what we'll need to match the part to your door.
We use necessary cookies to make our site work. We'd also like to set optional analytics cookies to help us improve it. We won't set optional cookies unless you enable them. Using this tool will set a cookie on your device to remember your preferences.
For more detailed information about the cookies we use, see our Cookies page